docs: x4xx: Update information on CPLD updating
This commit is contained in:
parent
99bb7b2127
commit
c85f3f872d
@ -539,11 +539,22 @@ Otherwise, let the boot continue as normal.
|
||||
<b>Caution! Updating the motherboard CPLD has the potential to brick your
|
||||
device if done improperly.</b>
|
||||
|
||||
After updating the filesystem, you may have to update your motherboard CPLD. If
|
||||
you forget to update the CPLD, MPM will fail to fully initialize and emit a
|
||||
warning. This is not critical, and the CPLD update can be performed later by
|
||||
following these same steps, but the device will not be usable until then.
|
||||
|
||||
Even though the CPLD may not require updating, it is recommended to always run
|
||||
these steps for a consistent update procedure.
|
||||
|
||||
You can update the motherboard (MB) CPLD by running the following command on
|
||||
the X410:
|
||||
|
||||
x4xx_update_cpld --file=<path to cpld-x410.rpd>
|
||||
|
||||
Note: Old filesystems may not contain this command. If you are performing a
|
||||
mender update, simply run these commands after the update.
|
||||
|
||||
Filesystems will usually contain a compatible `cpld-x410.rpd` file at
|
||||
`/lib/firmware/ni/cpld-x410.rpd`. If you're installing a new filesystem via
|
||||
mender, you may have to mount the new filesystem (before you boot into it) in
|
||||
|
||||
@ -420,6 +420,10 @@ The "software defined" mode can be enabled for the DSA tables by using the
|
||||
|
||||
\section zbx_updating_cpld Updating the ZBX CPLD
|
||||
|
||||
Note: You may need to update the ZBX CPLD after updating filesystems. If an
|
||||
update is required, MPM will fail to initialize, and provide a corresponding
|
||||
error message.
|
||||
|
||||
If you need to update the ZBX CPLD, you can do so by running the following command
|
||||
on the device:
|
||||
|
||||
@ -436,6 +440,21 @@ By default, the `cpld-zbx.rpd` file will be provided at
|
||||
`/lib/firmware/ni/cpld-zbx.rpd`. Note that after downloading the ZBX CPLD, you
|
||||
will need to completely shut down and power-cycle the device.
|
||||
|
||||
If you are updating the image during a filesystem update, i.e., after installing
|
||||
the new filesystem with Mender, but before rebooting, you will need to mount
|
||||
the new filesystem first and copy the image over:
|
||||
|
||||
mkdir /mnt/other
|
||||
mount /dev/mmcblk0p3 /mnt/other
|
||||
cp /mnt/other/lib/firmware/ni/cpld-zbx.rpd ~
|
||||
umount /mnt/other
|
||||
|
||||
Note that the other filesystem may be either `/dev/mmcblk0p2` or `/dev/mmcblk0p3`.
|
||||
You can now update to the new CPLD image:
|
||||
|
||||
zbx_update_cpld --file=~/cpld-zbx.rpd
|
||||
|
||||
|
||||
\subsection zbx_updating_cpld_details CPLD Programming: Details
|
||||
|
||||
Read this section if you want to create your own ZBX CPLD image, or require more
|
||||
|
||||